EarthSmart PIN™ | Production Intelligence Network

EarthSmart PIN™ · Production Intelligence Network

Every Production Begins With Operational Readiness.

Film, television, broadcast, and live-event operations bring hundreds of people and thousands of mobile assets together around temporary power, communications, facilities, equipment, refrigeration, and security.

EarthSmart PIN™ is the Production Intelligence Network designed to continuously observe the systems that determine whether the operation is ready.

PowerReadiness
EquipmentCondition
Cold ChainAssurance
SecurityAwareness
MobileInfrastructure
ContinuousObservation
The Hidden Risk

Production Does Not Fail All At Once.

It loses time one invisible condition at a time. Each condition begins as a signal. Without infrastructure capable of observing those signals, the problem stays invisible until a person discovers it, and by then the schedule is already absorbing the impact.

A Battery Never Charged

Discovered at 5:00 AM, after the truck is loaded and the crew is en route.

A Generator Faulted Overnight

Ran clean at wrap. Nobody was watching between wrap and call.

A Trailer Lost Power

Shore power dropped at 2:00 AM. Everything inside spent the night unpowered.

Cold Chain Drifted

Wardrobe, catering, medical, and effects assets outside their required range.

A Unit On the Wrong Lot

Delivered, signed for, and staged forty minutes from where it is needed.

Less Runtime Than Expected

The unit is charged. It is not charged enough for the day that was planned.

The production is continuously describing its own operational condition.

How EarthSmart PIN™ Works

The Difference Isn’t the Equipment. It’s When You Know.

The generator is the same generator. The trailer is the same trailer. The battery is the same battery. What changes is whether the condition becomes visible before it becomes operationally expensive.

Today
Equipment operates
A condition changes
Someone eventually discovers it
The schedule absorbs the impact
EarthSmart PIN
Equipment operates
Infrastructure observes continuously
Conditions requiring attention are surfaced
Production begins ready
Verified Before Crew Call
5:30 AM.

Crew call is 6:00. Before the first truck leaves the yard, operations already knows.

Operating System
Status
Condition
Mobile Power Fleet
Ready
Sufficient charge and runtime across all units
Generators
Ready
Reporting healthy operating conditions
Powered Trailers
Online
Remained online through the night
Cold Chain Assets
In Range
Within required temperature range
Critical Equipment
Located
Staged where the operation expects it
Exception Queue
Review
One condition already surfaced to operations
Illustrative readiness view

This is not a spreadsheet someone updated yesterday. It is the current operating condition of the production.

The Day Hasn’t Started. The Operation Already Has.

eMAX™ Mobile Power · The First Operating Node

Silent Power Was Only the Beginning.

eMAX Atlas™ 300 silent mobile power unit
eMAX Atlas 300™ · Silent Mobile Power
Atlas 300 · Technical Specification
Energy Capacity260 kWh
Cell ChemistryLFP
Rated Voltage832V
AC Output · US100 kW · 480V 3Ø · 60 Hz
AC Output · IEC100 kW · 400V · 50/60 Hz
DC Fast Charging120 kW · Dual Gun
DC Voltage RangeUp to 1000V
CoolingLiquid
Operating Temperature-22°F to 140°F
Enclosure RatingIP54 / IP55
Dimensions11′10″ × 7′3″ × 8′6″
Weight10,360 lbs
ObservationEarthSmart Integrated
Every eMAX unit is designed to report its own operational condition onto the Production Intelligence Network. Readiness is not inspected. It is observed.

Battery systems entered production because quieter sets needed an alternative to generators. EarthSmart looked at the same equipment and asked a more important operational question.

Will this unit be ready when production needs it?

Through EarthSmart PIN™, a mobile power system can continuously communicate the conditions that determine whether it is ready for deployment.

Charge State
Remaining Runtime
Charging Status
Electrical Health
Fault Conditions
Internal Temperature
Utilization
Readiness Status

Power Became Information.

Discovering a discharged battery after the truck reaches location is not simply an equipment failure. It is an operational failure that should have been visible before dispatch.

Verified Mobile Power Readiness EarthSmart PIN™ is designed to verify the condition of each connected mobile power unit before it leaves the yard, while it operates on location, and when it returns.
LFP ChemistryThermally stable, long cycle life, no cobalt.
Silent OperationNo engine noise, no exhaust, no idle.
Modular ArchitectureCapacity scales with the operation.
Key Features

Built for Scale. Observed for Readiness.

eMAX combines lithium iron phosphate battery technology with a modular platform built for demanding operating environments. Through EarthSmart PIN, each unit is designed to report its own operational condition continuously.

Scalable Architecture

Modular design lets capacity grow with the operation. The observation layer does not change as the fleet does.

Sized to the Operation

Three units across the range, from single-location deployments to extended multi-day operations.

Deploys Without IT

Arrives, powers on, and is designed to join the Production Intelligence Network. No venue-network pairing. No local IT configuration.

Built for Where Production Happens

Rugged construction and long-duration performance in the environments productions actually operate in.

Fast Turnaround

High-power DC charging returns units to readiness between production days rather than between weeks.

EarthSmart Integrated

Every unit is designed to report charge state, runtime, electrical health, fault conditions, and readiness onto the Production Intelligence Network.

The eMAX Range

One Platform. Three Sizes.

Same chemistry. Same cooling. Same thermal envelope. Same enclosure rating. Same integration. The operation chooses capacity, not architecture.

Specification Rover 150 Atlas 300 Titan 450
Energy Capacity 150 kWh 260 kWh 466 kWh
Rated Voltage 832V 832V 832V
Cell Chemistry LFP LFP LFP
DC Fast Charging Up to 1000V 120 kW dual gun 240 kW
Charge Time to 80% Approx. 2 hr 30 min
Cooling Liquid Liquid Liquid
Operating Temperature -22°F to 140°F -22°F to 140°F -22°F to 140°F
Enclosure Rating IP54 / IP55 IP54 / IP55 IP54 / IP55
Weight 5,950 lbs 10,360 lbs
Dimensions 5′3″ × 4′7″ × 6′7″ 11′10″ × 7′3″ × 8′6″
Observation EarthSmart Integrated EarthSmart Integrated EarthSmart Integrated

Specifications are nominal and subject to configuration. Contact us for deployment sizing.

Where Silent Power Changes What Is Possible
Residential Neighborhoods
Downtown Districts
Night Shoots
Hospitals and Schools
Parks and Protected Sites
Sound Stages
Mobile by Design

The Operating Layer Moves With Production.

Productions do not remain inside one facility. They move between yards, stages, locations, venues, and temporary operating environments. The infrastructure observing them has to move too.

Network Arrives

A production truck, command trailer, mobile office, or power unit is designed to carry an EarthSmart network presence into the operating environment.

Equipment Enters Coverage

Provisioned MAX Series™ devices connect as monitored equipment enters coverage. No venue-network pairing. No local IT configuration.

Conditions Become Visible

Power, movement, environmental conditions, security events, and equipment state are brought into one operational view.

The Production Stays in Control

The operation does not borrow the venue’s Wi-Fi, depend on temporary internet, or wait for another organization’s IT department.

The Operating Environment Arrives With the Production.
Continuous Observation

One Operational View. Every Critical Condition.

EarthSmart PIN is designed to continuously observe the systems that determine whether the operation is ready, degraded, exposed, or requires intervention.

Power Readiness

Battery systems, generators, mobile distribution, charging status, runtime, temperature, and electrical health.

Mobile Asset Readiness

Location, movement, availability, utilization, operating condition, and deployment status.

Trailer and Facility Readiness

Power, temperature, humidity, access, doors, environmental conditions, and after-hours status.

Cold Chain Assurance

Food service, wardrobe, medical supplies, makeup, special effects, and other temperature-sensitive production assets.

Security Awareness

Unauthorized movement, intrusion, tamper, access events, and after-hours activity.

Remote Operation Visibility

Location productions, temporary offices, broadcast environments, mobile command centers, and distributed production sites.

The Category

This Is Not Just Asset Tracking.

Operational Question Production Intelligence Asset Tracking Manual Check
Where is the assetContinuousContinuousOn request
Is it poweredContinuousNot typicalOn inspection
What is its conditionContinuousNot typicalOn inspection
How much runtime remainsContinuousNoEstimated
Is the environment within rangeContinuousNot typicalOn inspection
Has it been tampered withContinuousLimitedOn discovery
Is it ready to workContinuousNoAssumed
Location Is One Operational Signal. Readiness Is the Operating Question.
The Cost of Uncertainty

When Production Stops, Every Cost Keeps Getting Paid.

The cameras may stop. The costs do not.

Crew
Talent
Locations
Equipment
Transportation
Vendors
Catering
Security
Permits
Insurance
The Schedule Itself
Your team already knows what an hour of operational uncertainty costs. EarthSmart PIN exists to reduce the invisible conditions that create those hours.
The Foundation

Production Intelligence Without Borrowed Infrastructure.

EarthSmart PIN is designed to operate through the same EarthSmart infrastructure architecture supporting waterfront operations, commercial buildings, distributed energy systems, and critical environments.

7,000+Square Miles of Coverage
17States
FederalMaritime Operations Supported
OwnedEnd to End
Applications Evolve. Infrastructure Compounds.
One Operating Model

Built for Production. Extendable to Temporary Infrastructure.

Any environment assembled quickly, moved frequently, and expected to operate immediately faces the same readiness problem.

Film and Television
Broadcast
Live Entertainment
Disaster Response
Emergency Communications
Construction
Industrial Shutdowns
Field Operations
Production Is Where the Operating Model Begins. Not Where It Ends.
The Next Step

Start With What Your Operation Cannot See.

A Production Readiness Assessment identifies the equipment, power systems, mobile facilities, environmental conditions, and operational dependencies your team currently verifies manually, or does not observe at all.

We map the conditions that can stop production, determine where continuous observation creates the most immediate value, and define the infrastructure required to make readiness visible.

Observation Is the Foundation. Operational Readiness Is the Consequence.